HS310 General Servo Drive

PC software upgrade

Compatible with 17bit/23bit absolute encoder

Realize automatic parameter adjustment

Upgraded hardware and structure, smaller size

GET A QUICK QUOTE

HS310 General Servo Drive

● PC software upgrade
● Drive parameter copy
● Compatible with 17bit/23bit absolute encoder
● Continuing the superior performance of Honeywell products
● Realize automatic parameter adjustment
● Powerful bus communication function
● Smart setting
● Upgraded hardware and structure, smaller size

3kHz speed loop response bandwidth

Through the unique current loop algorithm, the bandwidth of the speed loop is effectively increased, and the setting time is greatly shortened. The fastest setting time can reach 1ms, which improves production efficiency.

Support full closed-loop mode

The fully closed-loop mode supports an external second encoder or grating ruler, which reduces errors caused by the mechanical transmission gap and improves positioning accuracy. All models are equipped with this function.

Automatic setting of the notch filter

● There is no need to perform complex vibration frequency measurement and analysis, and the notch filter can be quickly searched and automatically set during the parameter tuning process through the single parameter adjustment function of the host computer.
● Simple and easy to use, the fastest does not exceed 70ms. It can greatly reduce the noise and vibration caused by the mechanical resonance of the equipment, to achieve a faster response action. This function is widely used in machine tools.

Smart setting

Automatic gain adjustment, guided setting mode, the sequential setting can complete the setting of servo gain, simple and easy to use. Provides more adjustment modes, which can be adjusted according to different mechanical structure and process characteristics, so that the machine can reach a suitable state.

Powerful bus communication function

Support RS-485, EtherCAT, CANopen, MECHA-METROLINK, MECHATROLINK, and other mainstream buses.

Encoder Feedback
Encoder feedbackSerial encoder: absolute value encoder
Environmental conditions
Operating temperature0°C~55°C (55°C~60°C can be used after derating)
Storage temperature-20℃~ 65℃
Operating humidityBelow 95%RH (no freezing and condensation)
Storage humidityBelow 95%RH (no freezing and condensation)
Shock resistance4.9m/s
Impact strength19.6m/s
Protection classIP20
AltitudeLess than 1000m (1000m-2000m, need to reduce the rated value before use)
OtherNo electrostatic interference, strong electric field, strong magnetic field, radiation, etc.
Speed Control
Speed control range1: 5000 (the lower limit in the speed control range is the value under the condition that the rated torque load does not stop)
Speed volatilityLoad fluctuation:±0.01% or less of rated speed (load fluctuation: 0%~100%)
Voltage fluctuation:0% of rated speed (voltage fluctuation: ±10%)
Temperature fluctuation:±0.01% or less of rated speed (temperature fluctuation: 25℃±25℃)
Torque Control
Torque control accuracy±1% (reproducibility)
Soft start time setting0s~10s (acceleration and deceleration can be set separately)
Position Control
Feedforward compensation0%~100%
Command pulseCommand pulse shape: Including “pulse + direction”, “CW + CCW pulse sequence”, “A, B phase quadrature pulse” three command forms
Input form: Linear drive, open collector
Maximum input frequency: Differential Input: High Speed Max 4Mpps; Open Collector: Max 200Kpps
Communication Function
485Standard
CANOptional
USBComputer host computer, standard configuration, in line with USB2.0 specification (12Mpps)
Display Function
Display functionCHARGE, 8-segment LED*5 digits
Panel Operator Function
Panel Operator FunctionButton switch*4
Regeneration
RegenerationFunction can be built-in/external
Protective Function
Display functionOvercurrent, overvoltage, undervoltage, overload, regeneration fault, encoder disconnection, overtravel protection, etc.
Accessibility
AccessibilityGain adjustment, alarm recording, JOG operation, etc.
Encoder Pulse Frequency Division Output
Encoder pulse frequency division outputPhase A, Phase B, Phase C: Linear drive output, frequency-divided pulse number: 35~32767
File name
Documents type
File type
File size
Update
Download
LEAVE A MESSAGE